How to replace the ball valve of floor heating water distributor
The floor heating water distributor ball valve is a key component in the floor heating system and is responsible for controlling the flow of water in each circuit. When problems such as water leakage and inflexible switches occur in the ball valve, it must be replaced in time. This article will introduce in detail the replacement steps, precautions and common problems of the floor heating water distributor ball valve to help you complete the operation quickly.
1. Preparations before replacement

Before replacing the ball valve, you need to prepare the following tools and materials:
| Tools/Materials | Purpose |
|---|---|
| Adjustable wrench or pipe wrench | Disassemble old ball valve |
| Raw tape or sealant | Seal the new ball valve interface |
| New ball valve | Replace old valve |
| towel or container | Receive residual water |
2. Replacement steps
1.Turn off floor heating system: Make sure the floor heating system has stopped running, and close the main water inlet valve and return valve.
2.Pressure relief and drainage: Open the exhaust valve on the water distributor, release the pressure in the pipe, and use a towel or container to catch the remaining water.
3.Disassemble old ball valve: Use an adjustable wrench or pipe wrench to unscrew the connecting nut of the old ball valve, taking care to avoid damaging the water distributor interface.
4.Clean interface: Check whether there is any residual sealing material or rust on the water distributor interface, and clean it with sandpaper or cloth.
5.Install new ball valve: Wrap the raw tape around the thread of the new ball valve (clockwise), and then tighten it to the water distributor interface to ensure tightness.
6.Test tightness: Open the main valve, check whether the new ball valve is leaking, and retighten or add sealing material if necessary.
3. Precautions
| Things to note | Description |
|---|---|
| Valve direction | Make sure the ball valve opening and closing direction is consistent with the direction of water flow |
| sealing material | The raw material tape needs to be wrapped 5-8 times to avoid too much or too little |
| Velocity control | Use moderate force when tightening to prevent thread slippage |
| System restart | After replacement, it is necessary to exhaust air and gradually heat up to avoid air blockage in the pipeline. |
4. Frequently Asked Questions
Q1: What should I do if the ball valve still leaks after replacement?
A1: Check whether the raw material tape is wound evenly, or try to use sealant to enhance the sealing. If the interface is damaged, the water distributor parts need to be replaced.
Q2: What is the reason why the ball valve switch is not flexible?
A2: It may be that the valve core is corroded or impurities are stuck. You can try to lubricate or replace the valve with a new one.
Q3: Can I replace the ball valve by myself?
A3: If you have basic tools and operating knowledge, you can replace it yourself; otherwise, it is recommended to contact professional maintenance personnel.
5. Summary
When replacing the ball valve of the floor heating water distributor, attention should be paid to system pressure relief, sealing treatment and testing. Through the above steps and precautions, ball valve failure problems can be effectively solved. If you encounter difficulties during operation, you should consult professionals in time to ensure the safe operation of the floor heating system.
check the details
check the details